Parameters | Permissible values |
UA KIU-1 | UA KIU-2 | UA KIU-5 Unpackaged | KIU-28 KIU-51 | KIU-82 KIU-125 | KIU-82 KIU-126 | KIU-85 |
Operational frequency range | centimeter | (2923…3142) MHz | centimeter | (8910; 9030) MHz |
Input power, W | 0.007–0.02 | 1–10 | 5–50 | medium | low | medium | >(10÷15) |
Input impulsive power, KW, not less than | 0.020 | 50–120 | 355–525 | high | medium | high | >270 |
Filament voltage, V | 6.0–6.6 | 6.0–6.6 | 12–14.7 | 12.0–13.2 | 6.0–6.6 | 6.0–6.6 | 12.0–13.2 |
Filament current, A | 2–3 | 5–8 | 4–6 | 11.5–15 | 2.5 | 5–7 | 3.5–5.0 |
Cathode impulse voltage, KV, not exceeding | 1–1.5 | 14–17 | 50–55 | 24–26 | 1.0–1.5 | 14–17 | 27–33 |
Cathode impulsive current, A | 0.4–1.0 | 14–20 | 19–24 | 0.09–0.15 (medium) | 0.4–0.8 | 14–19 | 30÷50 |
Focusing solenoid current, A | - | - | 18–27 | - | - | - | - |
Voltage standing-rave ratio (VSWR) of load, not exceeding | 1.2 | 1.2 | 1.3 | 1.25 | 1.2 | 1.2 | 1.3 |
Warm-up time, min, not exceeding | 3 | 3 | 3 | 4 | 5 | 5 | 4 |
Cooling fluid temperature, C | - | 20÷80 | 55÷85 | 45÷65 | - | 20÷85 | 55÷85 |
Cooling type | natural | fluid | fluid | fluid | natural | fluid | fluid |
Minimum non-failure operation time, hr | 800 | 800 | 1500 | 1000 | 600 | 600 | 1000 |
Weight, kg, not exceeding | 2 | 5 | 35 | 30 | 1.4 | 4.5 | 13 |
Dimensions, mm | 114x76x 47.6 | 143x104.5 x230 | 256x885 | 292x172x375 | 105x70x 70 | 240x142x 104 | 160x220x 300 |
| | | | | | | | | | |